AYUDA EN LÍNEA
 WINDEVWEBDEV Y WINDEV MOBILE

Este contenido se ha traducido automáticamente.  Haga clic aquí  para ver la versión en inglés.
Ayuda / Centros de Control / Centro de Control del Usuario
  • Overview
  • How to?
  • Deploying in Push on the client computers
  • Services required on the target computers
  • Services required on the computer that performs the Push setup
WINDEV
WindowsLinuxJavaReportes y ConsultasCódigo de Usuario (UMC)
WEBDEV
WindowsLinuxPHPWEBDEV - Código Navegador
WINDEV Mobile
AndroidWidget Android iPhone/iPadIOS WidgetApple WatchMac Catalyst
Otros
Procedimientos almacenados
Overview
WDADMINEXE is used to deploy network applications in push via the "Push" tab. The setup while taking the Push into account is used to deploy an application on all the client computers of a network from a single management computer.
This setup mode is an option of the setup in local network with automatic update (Live Update).
How to?

Deploying in Push on the client computers

To deploy in push on the client computers:
  1. Start WDAdminExe (see above).
  2. Go to the "Push" tab of the main window:
    WDAdminExe: Push installation tab
  3. In "List of computers" (1), enter the username and the password of a Windows account with sufficient rights to enumerate the network computers.
    Remarks:
    • In an Active Directory, the username must have one of the following formats: DOMAIN\USER and/or USER@DOMAIN.
    • This account does not have to be an administrator.
    • You have the ability to store the connection information. If this option is used, it is important not to store the password of an administrator.
    • You also have the ability to load a list of computers from a text file. The text file can contain:
      • computer names or IP addresses.
      • comments in "// Comment" format.
      Each line must contain a name (or IP address) and a comment. For example:
      VIB //Machine de Vincent
      FP //Machine de Florence
  4. Click "List the computers" to validate the connection information and to start enumerating the client computers.
    Caution: depending on the LDAP strategies defined in Active Directory, import may be limited to 1,000 users. In this case, to remove this limitation, it is necessary to modify the LDAP MaxPageSize parameter. For more details, see https://support.microsoft.com/kb/315071.
  5. The criteria (2) and the list of groups (3) can be used to filter the computers to display. The list of groups is available on an Active Directory domain only.
  6. The table of computers (4) displays:
    • the client computers found,
    • the comment if text file is found.
    • the version number of the application if it is already installed,
    • the result of the previous Push setups.
  7. Select the client computers on which the application must be deployed in Push mode.
  8. Click "Start the PUSH setup..." to start the setup.
    The window for starting the setup is displayed:
    Starting the Push setup
  9. If several versions of the application are found in the reference setup, select the version that must be deployed in Push (1).
  10. The summary (2) displays the list of target computers for the setup. Some computers can be deleted from this list via the context menu.
  11. You can use a Windows account other than the one that was used to enumerate the computers if necessary (3).
  12. You can program the Push setup so that it is performed thereafter (4). This option allows you to automatically update a set of client computers outside the working hours for example.
  13. The validation of this window starts the Push setups. The progress can be monitored in the table of computers of the main window of WDADMINEXE.
Remark: An "Advanced" button lets you set the waiting time for push installations.. If several setups fail with timeout errors, you may have to adjust this parameter.

Services required on the target computers

Note: Depending on the version of Windows used, the names of these services in the Control Panel may vary.
The following services must be started on the target computers of the setup in Push mode:
  • File share ("lanmanserver" service)
  • Access to the remote registry ("RemoteRegistry" service)
Furthermore, the administrative share (ADMIN$) must exist. This share can be viewed in the management tool named "Computer management", in "System tools .. Shared folders .. Shares".

Services required on the computer that performs the Push setup

The "lanmanworkstation" service must be started on the computer that performs of the setup in Push mode:.
Versión mínima requerida
  • Versión 15
Comentarios
Haga clic en [Agregar] para publicar un comentario

Última modificación: 21/09/2024

Señalar un error o enviar una sugerencia | Ayuda local